How long will a 250 gallon propane tank run an 18 kW generator?

About 9 to 10 days for a typical home drawing 2 to 3 kW, starting from a full tank and stopping at 10%. Working at half load it lasts about 4.4 days, and flat out about 2.5 days.

Why the answer is a range

A 250 gallon tank is filled to 80% at most, which is 200 gallons (757 L). Stopping at 10% leaves 175 gallons (662 L) to burn. How fast the generator burns it depends on how hard it is working, and a home rarely asks an 18 kW generator for more than a fraction of its output. The maker publishes 1.65 gallons an hour at half load and 2.87 at full load; lighter loads are our estimate.

Average loadPropane per hourPer dayTank lastsFuel cost per day
1 kW0.57 gal14 gal (51.4 L)13 days$38
2 kW0.70 gal17 gal (63.7 L)10 days$47
3 kW0.84 gal20 gal (76.0 L)8.7 days$57
5 kW1.11 gal27 gal (101 L)6.6 days$75
9 kW, half load1.65 gal40 gal (150 L)4.4 days$112
18 kW, full load2.87 gal69 gal (261 L)2.5 days$194

Cost uses the US average residential price of $2.82 a gallon (EIA, November 2026). Burn below half load can vary by about 15% either way.

If the tank is not full

Gauge reading at the startUsable propaneLasts at 2 kWLasts at 3 kW
80% (just filled)175 gal10 days8.7 days
60%125 gal7.4 days6.2 days
40%75 gal4.5 days3.7 days
30%50 gal3.0 days2.5 days

Will the tank keep up in the cold?

Propane is stored as a liquid and has to boil off into vapor before the generator can burn it. Cold slows that down, and so does a low tank. This table checks a tank that is 30% full.

Outdoor temperatureVapor the tank can supplyResult for an 18 kW generator
40°F (4°C)395,000 BTU/hKeeps up, even at full output
20°F (-7°C)395,000 BTU/hKeeps up, even at full output
0°F (-18°C)197,000 BTU/hKeeps up at a typical load, not at full output
-15°F (-26°C)49,000 BTU/hCannot keep up

This generator needs about 77,000 BTU an hour at a 3 kW load and 263,000 at full output. More on this in propane in cold weather.

Try your own numbers

Units
A typical home averages 1 to 3 kW through an outage, far below the generator's rating.
A full tank reads 80%.
Burn at 3.0 kW0.84gal/hGive or take 15%
Propane per day20galAbout $57 a day
Runs for8.7daysLikely 8 to 10 days

Cold-weather check passed. At 20°F, this propane supply gives off enough vapor for the generator, even at full output.

Average load on the generatorBurn per hourPer dayTank lasts
1 kW0.57 gal13.6 gal13 days
2 kW0.70 gal16.8 gal10 days
3 kW0.84 gal20 gal8.7 days
5 kW1.11 gal27 gal6.6 days
9 kW (half load, published)1.65 gal40 gal4.4 days
18 kW (full load, published)2.87 gal69 gal2.5 days

Usable propane: 175 gal, from 80% down to 10% full. Half- and full-load burn are the maker's published figures; lower loads are estimated. How we calculate.

Common questions

How many gallons of propane does an 18 kW generator use per day?

Carrying a typical 2 to 3 kW household load, about 17 to 20 gallons (63.7 to 76.0 L) a day. At half load it uses 40 gallons a day and at full load 69.

What does it cost to run an 18 kW generator on propane?

At the US average residential price of $2.82 a gallon (EIA, November 2026), roughly $47 to $57 a day at a typical load, and about $112 a day at half load.

Is a 250 gallon tank big enough for an 18 kW generator?

For typical loads, yes, with a caveat in deep cold. At 0°F (-18°C) and 30% full the tank gives off about 197,000 BTU an hour: enough for a 3 kW household load (77,000 BTU an hour) but short of the 263,000 the generator needs at full output. Keep the tank fuller in winter, or step up a tank size.